Tables for burning sawdust

Firing table S
Art.-No. 8411 dimension: 550 x 850 x 400 mm high

Firing table L
Art.-No. 8412 dimension: 400 x 600 x 400 mm high

Gas burner for installation for cooking-kettles

Rechenbrenner AKK5
Ring burner AKR3

Ring gas burner Type AKR and Type AKK with safety cock switch , thermoelectric protection of the igniter and pilot burner

Type

heat load:

for litre

measure A in mm

measure B in mm

measure  C in mm

measure  D in mm

measure  E in mm

gas

Art.-No

AKR 1

13,8 kW

75

175

270

natural gas
liquid gas

8434

8454

AKR 2

16,3 kW

90

175

270

natural gas
liquid gas

8435

8455

AKR 3

18,6 kW

110

230

320

natural gas
liquid gas

8436

8456

AKR 4

20,9 kW

140

230

320

natural gas
liquid gas

8437

8457

AKR 5

25,6 kW

170

275

320

natural gas
liquid gas

8438

8458

AKR 6

30,2 kW

190

275

320

natural gas
liquid gas

8439

8459

AKK 1

14,0 kW

85

200

175

150

natural gas
liquid gas

8428

8448

AKK 2

20,9 kW

140

270

275

150

natural gas
liquid gas

8429

8449

AKK 3

27,9 kW

190

270

425

150

natural gas
liquid gas

8430

8450

AKK 4

34,9 kW

250

270

325

275

natural gas
liquid gas

8431

8451

AKK 5

41,9 kW

275

370

375

275

natural gas
liquid gas

8432

8452

AKK 6

55,8 kW

400

370

475

275

natural gas
liquid gas

8433

8453

The above dimensions are the outside dimensions of the burner with fittings.

The burner height is: 100 mm
Hinzu kommt die Ausbrandhöhe von 125 mm
Required combustion Height: 225 mm

If these are not available, please contact us. We will find a solution.

When using liquid gas for a performance above 16 kW, should be used a multi-cylinder system or a gastank.

Vorbau-Kochkesselbrenner Type ARA

  • for kettle and boiler
  • Prinzip des einblasenden Brenners
  • better efficiency
  • easy maintenance
  • not accident-sensitive
  • control device in stainless steel protective box (ARA Super)

 

Type ARA
safety cock switch , thermoelectric protection of the igniter, pilot burner and piezoelectric igniter

Type ARA Super
additionally with thermostatic regulating device consisting of a built solenoid valve and temperature controller rod 300 mm long.

Type

heat load

for litre
(indicative)

overall dimension of the subplate with cover
height x width (mm)

Size of the recess
height x width (mm)

Art.-No.

ARA 2

11,6 kW

75

350 x 300

150 x 60

8414

ARA 3

17,4 kW

100

350 x 300

150 x 60

8415

ARA 4

23,2 kW

150

400 x 350

250 x 60

8416

ARA 5

29,1 kW

200

400 x 350

250 x 60

8417

ARA 6

34,9 kW

250

400 x 350

150 x 120

8418

ARA 8

46,5 kW

300

400 x 350

250 x 120

8419

ARA 10

58,1 kW

400

400 x 350

300 x 120

8420

ARA 2 Super

17,4 kW

75

350 x 300

150 x 60

8421

ARA 3 Super

23,2 kW

100

350 x 300

150 x 60

8422

ARA 4 Super

29,1 kW

150

400 x 350

250 x 60

8423

ARA 5 Super

29,1 kW

200

400 x 350

250 x 60

8424

ARA 6 Super

34,9 kW

250

400 x 350

150 x 120

8425

ARA 8 Super

46,5 kW

300

400 x 350

250 x 120

8426

ARA 10 Super

58,1 kW

400

400 x 350

300 x 120

8427

 

When using liquid gas for a performance above 16 kW, should be used a multi-cylinder system or a gastank.

Burner for smokehouses

Smokehouses need usually a nominal of about 5,8 kW per m3 volume.

Consumption values per m3:
liquid gas: ca. 0,45 kg/h
natural gas: ca. 0,70 m3/h

These figures relate to the usual used smokehouses in butcherys. For different smokehouses, such as for fish or smoke towers etc. please contact us.
The smoke funnel should always be on the opposite side of the burner for ensure the heat evenly.
The cross-section of the smoke extraction usually have to be about 30 cm2 for each 5000 kcal/h = 5,8 kW. These benchmarks are only recommendations, the experts on the spot should examine the according circumstances.

Installation-burner for smokehouses Type AREB
with stainless steel case

Type AREB
safety cock switch , thermoelectric protection of the igniter, pilot burner and piezoelectric igniter

Type AREB Super
additionally with thermostatic regulating device consisting of a built solenoid valve and temperature controller rod 300 mm long.

Type

heat load

for volume
(indicative)

width
(mm)

height
(mm)

depth
(mm)

Mounting hole
(mm)

Gas

Art.-No.

AREB 2

11,6 kW

2 m3

300

200

370

200 x 300

*

8403

AREB 3

17,4 kW

3 m3

300

200

370

200 x 300

*

8404

AREB 4

23,2 kW

4 m3

400

200

370

200 x 400

natural gas

8405

AREB 4

23,2 kW

4 m3

400

200

370

200 x 400

liquid gas

8440

AREB 5

29,1 kW

5 m3

400

200

370

200 x 400

natural gas

8406

AREB 5

29,1 kW

5 m3

400

200

370

200 x 400

liquid gas

8460

AREB 2 Super

11,6 kW

2 m3

300

200

370

200 x 300

*

8407

AREB 3 Super

17,4 kW

3 m3

300

200

370

200 x 300

*

8408

AREB 4 Super

23,2 kW

4 m3

400

200

370

200 x 400

natural gas

8409

AREB 4 Super

23,2 kW

4 m3

400

200

370

200 x 400

liquid gas

8462

AREB 5 Super

29,1 kW

5 m3

400

200

370

200 x 400

natural gas

8410

AREB 5 Super

29,1 kW

5 m3

400

200

370

200 x 400

liquid gas

8461

 * Please specify the type of gas

When using liquid gas for a performance above 16 kW, should be used a multi-cylinder system or a gastank.

Abflammbrenner

Abflammbrenner AB 88
stainless steel-version
with a small device and shutoff valve
for propane gas 1,5 bar
heat load 46,5 kW
Art.-Nr. 8441

on request: completely
with gas safety hose 3000 mm long and pressure regulator 1,5 bar
Art.-Nr. 8441/8808

Burner for smokehouses ARB 56

Gas burner with protective box and cover with safety cock switch , thermoelectric protection of the igniter and pilot burner

total lenght
(mm)

tube lenght
(mm)

heat load

desing: cauterize

Art.-No.

1000

850

9,3 kW

right

8413

1000

850

9,3 kW

left

8473

650

500

7,0 kW

right or left - please specify when ordering

8717

750

600

7,0 kW

right or left - please specify when ordering

8718

850

700

7,0 kW

right or left - please specify when ordering

8719

1250

1100

10,5 kW

right or left - please specify when ordering

8720

1500

1325

11,6 kW

right or left - please specify when ordering

8721

1750

1575

12,8 kW

right or left - please specify when ordering

8722

2000

1825

14,0 kW

right or left - please specify when ordering

8723

2250

2075

15,1 kW

right or left - please specify when ordering

8724

2500

2325

16,3 kW

right or left - please specify when ordering

8725

2750

2525

17,4 kW

right or left - please specify when ordering

8726

3000

2825

18,6 kW

right or left - please specify when ordering

8727