Ring gas burner Type AKR and Type AKK with safety cock switch , thermoelectric protection of the igniter and pilot burner
Type | heat load: | for litre | measure A in mm | measure B in mm | measure C in mm | measure D in mm | measure E in mm | gas | Art.-No |
---|---|---|---|---|---|---|---|---|---|
AKR 1 | 13,8 kW | 75 | 175 | 270 | natural gas | 8434 | |||
AKR 2 | 16,3 kW | 90 | 175 | 270 | natural gas | 8435 | |||
AKR 3 | 18,6 kW | 110 | 230 | 320 | natural gas | 8436 | |||
AKR 4 | 20,9 kW | 140 | 230 | 320 | natural gas | 8437 | |||
AKR 5 | 25,6 kW | 170 | 275 | 320 | natural gas | 8438 | |||
AKR 6 | 30,2 kW | 190 | 275 | 320 | natural gas | 8439 | |||
AKK 1 | 14,0 kW | 85 | 200 | 175 | 150 | natural gas | 8428 | ||
AKK 2 | 20,9 kW | 140 | 270 | 275 | 150 | natural gas | 8429 | ||
AKK 3 | 27,9 kW | 190 | 270 | 425 | 150 | natural gas | 8430 | ||
AKK 4 | 34,9 kW | 250 | 270 | 325 | 275 | natural gas | 8431 | ||
AKK 5 | 41,9 kW | 275 | 370 | 375 | 275 | natural gas | 8432 | ||
AKK 6 | 55,8 kW | 400 | 370 | 475 | 275 | natural gas | 8433 |
The above dimensions are the outside dimensions of the burner with fittings.
The burner height is: 100 mm
Hinzu kommt die Ausbrandhöhe von 125 mm
Required combustion Height: 225 mm
If these are not available, please contact us. We will find a solution.
When using liquid gas for a performance above 16 kW, should be used a multi-cylinder system or a gastank.
Type ARA
safety cock switch , thermoelectric protection of the igniter, pilot burner and piezoelectric igniter
Type ARA Super
additionally with thermostatic regulating device consisting of a built solenoid valve and temperature controller rod 300 mm long.
Type | heat load | for litre | overall dimension of the subplate with cover | Size of the recess | Art.-No. |
---|---|---|---|---|---|
ARA 2 | 11,6 kW | 75 | 350 x 300 | 150 x 60 | 8414 |
ARA 3 | 17,4 kW | 100 | 350 x 300 | 150 x 60 | 8415 |
ARA 4 | 23,2 kW | 150 | 400 x 350 | 250 x 60 | 8416 |
ARA 5 | 29,1 kW | 200 | 400 x 350 | 250 x 60 | 8417 |
ARA 6 | 34,9 kW | 250 | 400 x 350 | 150 x 120 | 8418 |
ARA 8 | 46,5 kW | 300 | 400 x 350 | 250 x 120 | 8419 |
ARA 10 | 58,1 kW | 400 | 400 x 350 | 300 x 120 | 8420 |
ARA 2 Super | 17,4 kW | 75 | 350 x 300 | 150 x 60 | 8421 |
ARA 3 Super | 23,2 kW | 100 | 350 x 300 | 150 x 60 | 8422 |
ARA 4 Super | 29,1 kW | 150 | 400 x 350 | 250 x 60 | 8423 |
ARA 5 Super | 29,1 kW | 200 | 400 x 350 | 250 x 60 | 8424 |
ARA 6 Super | 34,9 kW | 250 | 400 x 350 | 150 x 120 | 8425 |
ARA 8 Super | 46,5 kW | 300 | 400 x 350 | 250 x 120 | 8426 |
ARA 10 Super | 58,1 kW | 400 | 400 x 350 | 300 x 120 | 8427 |
When using liquid gas for a performance above 16 kW, should be used a multi-cylinder system or a gastank.
Smokehouses need usually a nominal of about 5,8 kW per m3 volume.
Consumption values per m3:
liquid gas: ca. 0,45 kg/h
natural gas: ca. 0,70 m3/h
These figures relate to the usual used smokehouses in butcherys. For different smokehouses, such as for fish or smoke towers etc. please contact us.
The smoke funnel should always be on the opposite side of the burner for ensure the heat evenly.
The cross-section of the smoke extraction usually have to be about 30 cm2 for each 5000 kcal/h = 5,8 kW. These benchmarks are only recommendations, the experts on the spot should examine the according circumstances.
Installation-burner for smokehouses Type AREB
with stainless steel case
Type AREB
safety cock switch , thermoelectric protection of the igniter, pilot burner and piezoelectric igniter
Type AREB Super
additionally with thermostatic regulating device consisting of a built solenoid valve and temperature controller rod 300 mm long.
Type | heat load | for volume | width | height | depth | Mounting hole | Gas | Art.-No. |
---|---|---|---|---|---|---|---|---|
AREB 2 | 11,6 kW | 2 m3 | 300 | 200 | 370 | 200 x 300 | * | 8403 |
AREB 3 | 17,4 kW | 3 m3 | 300 | 200 | 370 | 200 x 300 | * | 8404 |
AREB 4 | 23,2 kW | 4 m3 | 400 | 200 | 370 | 200 x 400 | natural gas | 8405 |
AREB 4 | 23,2 kW | 4 m3 | 400 | 200 | 370 | 200 x 400 | liquid gas | 8440 |
AREB 5 | 29,1 kW | 5 m3 | 400 | 200 | 370 | 200 x 400 | natural gas | 8406 |
AREB 5 | 29,1 kW | 5 m3 | 400 | 200 | 370 | 200 x 400 | liquid gas | 8460 |
AREB 2 Super | 11,6 kW | 2 m3 | 300 | 200 | 370 | 200 x 300 | * | 8407 |
AREB 3 Super | 17,4 kW | 3 m3 | 300 | 200 | 370 | 200 x 300 | * | 8408 |
AREB 4 Super | 23,2 kW | 4 m3 | 400 | 200 | 370 | 200 x 400 | natural gas | 8409 |
AREB 4 Super | 23,2 kW | 4 m3 | 400 | 200 | 370 | 200 x 400 | liquid gas | 8462 |
AREB 5 Super | 29,1 kW | 5 m3 | 400 | 200 | 370 | 200 x 400 | natural gas | 8410 |
AREB 5 Super | 29,1 kW | 5 m3 | 400 | 200 | 370 | 200 x 400 | liquid gas | 8461 |
* Please specify the type of gas
When using liquid gas for a performance above 16 kW, should be used a multi-cylinder system or a gastank.
Abflammbrenner AB 88
stainless steel-version
with a small device and shutoff valve
for propane gas 1,5 bar
heat load 46,5 kW
Art.-Nr. 8441
on request: completely
with gas safety hose 3000 mm long and pressure regulator 1,5 bar
Art.-Nr. 8441/8808
Gas burner with protective box and cover with safety cock switch , thermoelectric protection of the igniter and pilot burner
total lenght | tube lenght | heat load | desing: cauterize | Art.-No. |
---|---|---|---|---|
1000 | 850 | 9,3 kW | right | 8413 |
1000 | 850 | 9,3 kW | left | 8473 |
650 | 500 | 7,0 kW | right or left - please specify when ordering | 8717 |
750 | 600 | 7,0 kW | right or left - please specify when ordering | 8718 |
850 | 700 | 7,0 kW | right or left - please specify when ordering | 8719 |
1250 | 1100 | 10,5 kW | right or left - please specify when ordering | 8720 |
1500 | 1325 | 11,6 kW | right or left - please specify when ordering | 8721 |
1750 | 1575 | 12,8 kW | right or left - please specify when ordering | 8722 |
2000 | 1825 | 14,0 kW | right or left - please specify when ordering | 8723 |
2250 | 2075 | 15,1 kW | right or left - please specify when ordering | 8724 |
2500 | 2325 | 16,3 kW | right or left - please specify when ordering | 8725 |
2750 | 2525 | 17,4 kW | right or left - please specify when ordering | 8726 |
3000 | 2825 | 18,6 kW | right or left - please specify when ordering | 8727 |